Bin-fill Observations and Gateway Receipts
Bin-fill Observations and Gateway Receipts
Accept the last live report
- Current decision
- Accepted fill-level reading and battery flag
- History
- Last accepted observation retained
The gateway has accepted a reading from a node it expects to report periodically.
Missed receipt and freshness review
- First · Freshness check pending
- The gateway missed an expected receipt and retains the last accepted reading while it checks its age.
- Related sources
- Available
- Then · Reading fails the freshness check
- The source is unavailable for the current decision.
- History
- Last accepted record retained
- Fallback
- Evidence in use for the current decision
- New complete reading
- Returned buffered records
- Role or schedule change
- Silence past the review rule
The gateway missed an expected report and is checking the last reading’s freshness.The gateway first misses an expected report. When the last accepted reading becomes stale, use fallback evidence for the current decision.
Track a buffered record on return
- Current decision
- Source unavailable. Fallback evidence in use.
- History
- Returned record pending validation
The gateway hears from the node again. The buffered record describes an earlier observation.
Validate before filling a historical slot
- Current decision
- Source unavailable. Fallback evidence in use.
- History
- Valid buffered reading placed by observation time. Too old for current use.
- Duplicate
- No observation added
- Invalid example
- Review tray. Excluded from history and current decision.
- Observation time
- Receive time
- Sequence order
- Duplicate handling
- Missing intervals
Check the returned reading before adding it to history.The validated buffered reading fills its historical observation slot. The gateway receipt gap remains, and a duplicate adds no observation.
Conditional fresh-record branch
- Current decision
- Update from the separate complete record after validity and observation-time freshness checks. Clear fallback on this branch.
- History
- Valid buffered reading remains in its slot. Other missing slots remain marked.
- Invalid example
- Review tray only. Excluded from history and current decision.
- Another late return
- Repeated sequence gaps
- Duplicate handling changes
- Conflict with related evidence
A separate record can update the current decision if it is valid and fresh. The earlier buffered reading remains historical.
The gateway has accepted a reading from a node it expects to report periodically.
Technical boundaries. The timelines arrange bin-fill events in labeled slots and give no clock times or numeric freshness limit. The return sequence shows a validated buffered reading, a duplicate and an invalid example. Updating the current decision requires a separate record that passes validity and freshness checks.