Check Greenhouse Sensor Installations
Check Greenhouse Sensor Installations
Check Greenhouse Sensor Installations
Installed sensorsCheck fan vibration
Check damp air
Check door state
Fan · same accelerometer, axis, sample rate, filtering and operating condition
Direct coupling to housing.
Motion of loose guard.
Record a baseline during known-good fan operation at this mount
Use the installed housing mount.
Liquid water on package.
Monitored channel · 99% RH
RH means relative humidity. Status: needs verification.
Nearby reference: protected from direct spray and sampling representative air.
Verification pending
Check part’s condensation limits.
Observe recovery after wetting.
Compare with reference.
Light changed · Door stayed closed
Lamp brightness held constant
Reed sensor fixed to the frame.
Magnet moves with the door. Controller reads Open.
Check fan vibration
Check damp air
Check door state
Make your prediction
Evidence to keep?
What change calls for a retest?
Fan vibration · housing mount
Keep: the mount and the known-good operating baseline.
Retest if: the mount changes.
Damp air · humidity package
Keep: condensation limits and recovery compared with the reference.
Retest if: enclosure or mist exposure changes.
Door state · reed sensor and magnet
Keep: the reported state at each observed door position.
Retest if: magnet alignment or wiring changes.
Each greenhouse decision needs evidence of a specific physical change.
Technical boundaries. The fan comparison holds the accelerometer, axis, sample rate, filtering and operating condition constant. The mist sequence provides an example reading and shows how to check recovery. The part’s condensation limits and the recovery result need to be established for the installed package.