Interactive: One-Point Offset Calculator

Interactive: One-Point Offset Calculator

animation
sensors
Try Keep Known Reference Value (°C) at 0 and Sensor Reading at Reference (°C) at 2.3. Move Test Raw Reading (°C) from 25.0 to see the same correction applied elsewhere.
Observe The default offset is 2.30°C, labelled as reading high. A raw test value of 25.0°C becomes 22.70°C after correction.
Explain Sensor Reading at Reference (°C) minus Known Reference Value (°C) sets the offset. The tool subtracts that offset from Test Raw Reading (°C).

Technical boundaries. One-point correction assumes the error is a constant additive offset throughout the range. All three sliders span −50 to 150°C; gain error, nonlinearity and reference uncertainty are not estimated.

Interactive: One-Point Offset Calculator.

Enter a reference and the sensor reading at that point. The calculator finds the offset and applies it to a test reading; a separate reference test is still needed.