DS18B20 Measurement Path

DS18B20 Measurement Path

TipPhysics Phoebe, Physics and measurement-foundations expertCheckpoint: DS18B20 Measurement Path

A dependable DS18B20 reading requires a discovered bus address, a completed conversion, and validation of the returned value before it enters the application.

You now know:

  • Each DS18B20 has an address, so devices can share a bus.
  • A 12-bit conversion can take 750 ms. Divide the raw value by 16.
  • 85 °C may be the power-on value or a real reading. Check that conversion finished.
  • The DallasTemperature library uses -127 °C as an error value. Check the bus and CRC.