MOSFET Thermal Calculator

MOSFET Thermal Calculator

animation
electronics
Try Use Motor Current (A) of 2, Assumed Rds(on) (mΩ) of 50 and Thermal Resistance (°C/W) of 62.5, then vary current.
Observe At Ambient Temperature (°C) of 25, the initial results are 0.100 V drop, 200.0 mW loss and 37.5 °C junction temperature.
Explain Motor Current (A) is squared and multiplied by resistance to obtain loss; thermal resistance converts that loss into a rise above ambient.

Technical boundaries. The estimate assumes the entered on-resistance remains constant and applies a steady thermal resistance. PWM duty cycle and drain-transition losses are absent, and the fixed 150 °C comparison is not a device-specific rating.

TipExplore: MOSFET Thermal Calculator

The power dissipation formula (P=I2×Rds(on)P = I^2 \times R_{ds(on)}) estimates conduction loss when the on-resistance is known at the applied gate voltage. Adjust the parameters below to explore conditional scenarios; the calculator does not include PWM duty cycle or drain-transition losses.

Back to the chapter