Relay and solenoid checkpoints
Relay and solenoid checkpoints
animation
actuators
Tip
Checkpoint: Relay Interfaces
Checkpoint: Relay Interfaces
You now know:
- A relay coil that needs 50-100 mA exceeds a typical GPIO limit, so the GPIO should command a transistor or MOSFET driver.
- NO contacts default off, while NC contacts default on; the safest default depends on what failure state the load can tolerate.
- Relay contacts and relay coils are separate ratings: a 5 V or 12 V coil can switch a much higher-voltage load only when the contact rating allows it.
Tip
Checkpoint: Coil Energy
Checkpoint: Coil Energy
You now know:
- Relays and solenoids are inductive loads, so turn-off energy needs a deliberate path.
- The chapter’s 100 mH, 80 mA coil stores 0.32 mJ, but an ideal 1 us turn-off can imply an 8000 V spike.
- A flyback diode protects the driver, while snubbers, MOVs, or TVS parts handle different contact or AC-load spike paths.
Tip
Checkpoint: Switching Choices
Checkpoint: Switching Choices
You now know:
- SSRs switch silently and avoid mechanical wear, but their 1-2 V output drop can become heat at high current.
- A 5 A fan with a 28 A, 100 ms inrush needs contact ratings that cover startup, not just steady-state current.
- The sprinkler example chooses solid-state outputs because 7,300 cycles, outdoor wiring, and quiet operation matter as much as raw part count.