Checkpoint: Average Command

Checkpoint: Average Command

animation
actuators
pwm
TipMotor Max, Actuation and safe-control domain expertCheckpoint: Average Command

You now know:

  • Duty cycle is the percent of each period spent HIGH; at 50% duty and a 5 V supply, the average actuator voltage is 2.5 V.
  • Frequency sets how often the periods repeat; at 5kHz, each period is 200 microseconds, not a new voltage level.
  • The 75% duty quiz uses the same rule on a 12V motor: 12V x 0.75 = 9V.

Back to the chapter