← Back to the chapter · Previous detail

Technical detail · Context-Aware Energy Management

Why the watcher cannot draw zero current

At 290 K, thermal noise density is about -174 dBm/Hz. A 200 kHz wake channel therefore contains about 8.01×10−168.01\times10^{-16} W, or -121.0 dBm, before the front end adds its own noise. Widening the channel to 1 MHz raises that floor by 7 dB. The chapter’s 50 microamp watcher at 3.3 V also consumes 165 microwatts, or 3.96 mWh each day, before it triggers anything.