← Back to the chapter · Next detail →

Technical detail · Automotive Qualification: Mission Profiles

Interpret the TPMS pressure and cell ratings

A diaphragm is a thin flexible wall that bends when pressure pushes on it. Edge strain is the small stretch at its edge; microstrain (µε) expresses that stretch in millionths. Gauge factor tells how strongly a strain-sensitive resistor changes resistance when stretched. Excitation is the voltage supplied to the sensor circuit. A sensing bridge is an arrangement of resistors that turns small resistance changes into a measurable voltage.

The mathematical gist. A catalog-typical 3.00 bar TPMS case bends a 25.0 µm silicon diaphragm by 1.22 µm and produces 488 µε edge strain. With gauge factor 100 and 3.0 V excitation, the simplified bridge gives 146 mV. Separately, a 220 mAh, 3.0 V cell stores 0.660 Wh and retains 86.0% after ten years at 1.5% annual self-discharge.

← Back to the chapter · Next detail →