Technical detail · Accelerometer Datasheets: Selection Evidence

Range, code count, and the sampling boundary

At a fixed 4.00 mg/LSB, doubling the accelerometer range doubles the required code count: ±2 g needs 1,000 codes and 10 bits, while ±16 g needs 8,000 codes and 13 bits. At 100 samples per second, the Nyquist ceiling is 50 Hz: sampling must be faster than twice the highest frequency you want to resolve. A filter must also limit input motion above that frequency, or it can appear falsely as slower motion in the samples.