← Back to the chapter · Previous detail · Next detail →
Technical detail · IoT Mathematics: Fusion and Sampling Decisions
Select the motor sampling rate
Background: 1800 RPM motor (30 Hz rotation), 4-blade fan
Step 1: Identify Frequency Components
From Section B.1 (Exponential Functions) and mechanical theory:
- Fundamental: Motor rotation = 30 Hz
- Blade pass frequency: 4 blades x 30 Hz = 120 Hz
- Harmonics: In this example, include up to the third harmonic of the 120 Hz blade-pass component = 120 x 3 = 360 Hz; shaft imbalance is primarily at the 30 Hz rotation rate.
Step 2: Apply Nyquist Theorem
Step 3: Add Safety Margin
For this example, use 2.5x the 720 Hz Nyquist minimum to allow filter roll-off.
Step 4: Select Standard ADC Rate
Common options: 1 kHz, 2 kHz, 5 kHz, 10 kHz
Decision: 2 kHz (exceeds requirement, standard IC availability)