← Back to the chapter · Previous detail · Next detail →

Technical detail · IoT Mathematics: Fusion and Sampling Decisions

Compare data volume and ADC energy

Sampling RateData Rate (16-bit samples)ProsCons
720 Hz (minimum Nyquist)11,520 bits/secLow power, minimal storageNo margin, aliasing risk
2 kHz (recommended)32,000 bits/secSafe margin, standard ADCs2.8x data volume
10 kHz (over-sampled)160,000 bits/secDigital filtering, noise averaging14x data volume, unnecessary

Energy Impact (from Section A.2, Energy Budget):

ADC power: 5 mW active, conversion time: 10 us

720 Hz: Duty cycle = 720 x 10 us = 0.72%, average power = 5 mW x 0.0072 = 36 uW 2 kHz: Duty cycle = 2000 x 10 us = 2%, average power = 100 uW 10 kHz: Duty cycle = 10%, average power = 500 uW

Battery life impact (2000 mAh at 3.3V):

2 kHz: 100 uW -> 30 uA -> 2000/0.03 = 66,667 hours = 7.6 years 10 kHz: 500 uW -> 150 uA -> 13,333 hours = 1.5 years

Decision: In this ADC-only model, 2 kHz sampling provides a 2.8x margin over the Nyquist minimum while preserving 7+ years of battery life. In this ADC-only model, 10 kHz over-sampling reduces the projected battery life by about 80% with no required signal-quality benefit for the stated 360 Hz signal.