Define laparoscopic movement metrics

Record each laparoscopic metric separately so a movement summary can be distinguished from a skill claim. Task duration is the elapsed time T; angular distance is the sum of frame-to-frame angle changes theta; average speed is theta / T; and average angular acceleration is omega / T. Motion smoothness is a normalized integral of instantaneous jerk, computed from the second derivative of frame-to-frame angle differences and averaged across left and right hands, with values closer to zero indicating smoother motion. Handedness subtracts left-hand frame distance from right-hand frame distance and averages the difference after multiplying by frame rate. Speed variance measures variance in consecutive-frame angular distances, and ambidexterity measures the correlation between left and right frame speeds, so positive correlation means concurrent instrument motion while negative correlation means one instrument dominates at a time.