Technical detail · Edge Data: Sampling and Statistical Compression
Battery and payload budget
The worked temperature case uses a 2,500 mAh battery and one reading per minute. LoRa transmission draws 120 mA for 1.5 s per packet; sleep contributes 0.01 mAh per hour.
Sending all 60 readings each hour uses mAh per hour for transmission. Including sleep gives 3.01 mAh per hour, so battery life is hours, about 35 days.
Sending one summary every 15 minutes means four transmissions per hour. Transmission then uses mAh per hour. Including sleep gives 0.21 mAh per hour: hours, about 496 days or 1.4 years. The rounded comparison is times longer, often described as 14-fold.
Raw payload traffic is B/hour, or 1.2 kB/hour and 28.8 kB/day. Four 32-byte min/max/mean/count summaries use 128 B/hour, about 3.1 kB/day. The rounded bandwidth ratio is .
Transmission dominates this simplified budget. These estimates do not include every sensing or processing cost, nor establish that summary loss is acceptable: trend analysis must still work with the retained evidence.