← Back to the chapter · Previous detail · Next detail →
Technical detail · Validation and Outlier Detection
Precision, standard error, and error limits
Precision has two related meanings that must not be mixed. Repeated sensor readings can be tightly grouped, which is measurement repeatability, while an estimate such as a sample mean can vary little across hypothetical repeated samples, which is statistical precision. For an independent sample mean, the estimated standard error is
and a confidence-interval margin of error has the general form
The interval is the estimate plus or minus that margin. More independent observations usually reduce sampling error, but they do not correct calibration bias, missing sites, selective device survival, or a flawed measurement procedure. Time-series readings from one sensor and readings clustered within one gateway are correlated; counting them as independent makes the standard error look artificially small. Use a design-aware standard error, block or cluster resampling, or a model that represents the dependence.
Suppose a team estimates mean temperature error after a firmware change. The evidence record should state the estimator, sampling unit, number of independent units, variability estimate, confidence level, critical-value method, and resulting interval. If thousands of readings came from only a few devices, the device—not each timestamp—is often the relevant independent unit. This matters because a narrow interval is only a precise statement about the sampled design; it is not proof that the sensor is accurate or that the result generalizes to the fleet.