← Back to the chapter · Next detail →

Technical detail · Sensor Fusion Foundations

Why a smaller error band can hide shared bias

The independence assumption is easy to overstate. Suppose sensor A reports 10.0 units with random uncertainty of about 0.5 units and sensor B reports 10.4 units with the same uncertainty. If their errors are independent, a simple average gives 10.2 units and the random uncertainty can shrink because the noise sources partly cancel. But if both sensors were calibrated with the same offset reference that is +0.4 units high, the average is still biased. The fused output may display a smaller random-error band while the real value remains shifted in the same direction.

Shared-bias example
sensor A: 10.0 units, random uncertainty about 0.5
sensor B: 10.4 units, random uncertainty about 0.5
simple average: (10.0 + 10.4) / 2 = 10.2

if errors are independent:
random noise is reduced by averaging

if both sensors share a +0.4 calibration bias:
the average still carries the same hidden offset
publish the common calibration source as a risk,
not just the smaller-looking random uncertainty

← Back to the chapter · Next detail →