Sensor Processing Checkpoints

Knowledge check · self-test
Sensor Processing Checkpoints
Check errors where the application acts.
Check errors where the application acts.
::: {.callout-tip} ##
Checkpoint: Filter Choice {.depth-l0 data-narration="suspended-until-rerecord"}
Choose a filter based on whether the unwanted error is random noise, an isolated spike, or a real changing signal that must remain responsive.
An exponential moving average (EMA) is a running estimate: each new reading is blended with the estimate from the previous reading. In a Kalman filter, Q is the uncertainty assigned to changes in the state being tracked, while R is the uncertainty assigned to each measurement.
You now know:
- A causal N-sample moving average has group delay (N-1)/2 samples; for N=10 at 100 Hz, this is 45 ms.
- EMA keeps only 1 float, or 4 bytes, while a 10-sample moving average stores 40 bytes.
- Median filtering is the first stage for spikes, while Kalman filtering belongs where Q, R, and changing state are meaningful.
:::::: {.callout-tip}
##
Checkpoint: Calibration {.depth-l0 data-narration="suspended-until-rerecord"}
Calibration estimates a correction from references and checks whether residual error meets the decision tolerance.
You now know:
- Two-point calibration uses a low and high reference so the firmware can correct both offset and gain.
- The interactive example maps raw ADC endpoints 512 and 3584 onto actual values 0 and 100.
- The soil example maps dry ADC 2988 and field-capacity ADC 1515 onto 0-60% moisture, then checks the 30% irrigation trigger.
:::::: {.callout-tip}
##
Checkpoint: Pipeline Readiness {.depth-l0 data-narration="suspended-until-rerecord"}
A ready processing pipeline preserves valid samples, rejects impossible data, and records enough context to reproduce a decision.
You now know:
- A pipeline gathers readings, checks them, and prepares them for use.
- The label quiz shows the steps from input to analysis.
- Sampling comes first. Filtering and calibration cannot recover a signal that was missed.
:::Back to Sensor Processing: Filter Selection and Validation: Sensor Calibration