TryPress Step once from the warehouse setup to see what the desk-side capture shows when the tracker sends no warning.
Warehouse test: A warning must reach the local desk within two seconds when one radio path is blocked.
Set up the warehouse test
Packet capture
Schematic warning route⊘ Blocked radio path
Warning packet
TrackerUpstream capture pointSuspected loss segmentLocal desk Desk-side capture point
Where would you capture next?
✓ Match the test warning across captures in the same test window✓ Check capture coverage and filters
Trigger-to-receipt timing
Use a shared clock or align the trigger and desk application clocks.
Case
Test trigger recorded
Warning receipt confirmed by local-desk application
A
✓ Recorded
○ Unconfirmed
Receipt timestamp:
B
✓ Recorded
○ Unconfirmed
Receipt timestamp:
Deadline not demonstrated
ObserveIn frame 4, neither desk-side trace shows a matching warning. In frame 5, the upstream trace shows a matching packet for Case B while Case A still shows no match.
ExplainThe two cases look alike at the desk-side capture because neither delivers a packet to that capture point. The upstream match in frame 5 shows the warning reached that interface.
Technical boundaries. The schematic illustrates two possible failure cases with a radio path blocked. The exact failure location and cause remain unresolved. Both application receipt timestamps are blank, so checking the two-second deadline would require confirmed receipt and a shared clock or aligned clocks.