Routine reports and alert wakes
Routine reports and alert wakes
Try Start with Step to reveal the original schedule and locate its first radio start after the shared opening report.
Routine reports and alert wakes
Wake policyTemperature sketch · dashed line marks the alert threshold
Scheduled report starts; common elapsed-time scaleOrigin10 min20 min30 min
Original
Hybrid
Routine
- Normal reports no more than 30 minutes apart
Alert
- Report immediately on threshold crossing
- Comparator → microcontroller → radio
Temperature sketch · dashed line marks the alert threshold
Scheduled starts; shared elapsed-time scaleOrigin10 min20 min30 min
OriginalReportReportReportReport
HybridShared report
Routine starts
- Shared opening report; then 10, 20 and 30 minutes
- Radio active at each scheduled start
Temperature
- Slowly varying schematic; no threshold crossing
Scheduled starts; shared elapsed-time scaleOrigin10 min20 min30 min
OriginalReportReportReportReport
HybridReport——Health report
Routine
- Timer wakes for health report at 30 minutes
- Comparator monitors threshold while microcontroller sleeps
Scheduled startsOrigin10 min20 min30 min
OriginalReportReportReportReport
HybridReport——Batch
Timer wake
- Timer → microcontroller
- Batch available routine samples in one radio session
- Record battery voltage and retry count
- Sample timing unspecified
Temperature crosses the alert threshold between routine reports
- Comparator detects crossing
- MCU wakes
- Radio sends
- Useful alert delivered
CrossingUseful alert delivery
Latency to measure · unscaled
Scheduled report starts; common elapsed-time scaleOrigin10 min20 min30 min
OriginalShared reportReportReportReport
HybridShared report——Health report
Alert path; latency unscaledCrossingWakeSendDelivery
AlertComparatorMicrocontrollerRadioUseful alert delivered
Alert path
- Comparator detects threshold crossing
- Microcontroller wakes and handles alert
- Radio sends; useful alert delivered
- Measure crossing-to-delivery latency; do not wait for batch
Scheduled report starts; common elapsed-time scaleOrigin10 min20 min30 min
OriginalShared reportReportReportReport
HybridShared report——Health report
Radio starts
- Scheduled starts and total starts including alerts: collect separately
Energy evidence
- Routine and alert processing; message time
- Comparator and pull-up sleep current
Service evidence
- Report spacing; alert latency; data quality; missed events
Reporting contract
The temperature node must send normal reports no more than 30 minutes apart and report immediately when temperature crosses the alert threshold.
Observe The Original row adds reports at 10, 20 and 30 minutes, while the Hybrid row shows only a health report after the opening report, at 30 minutes.
Explain The timer handles routine reports every 30 minutes, and the comparator watches for crossings during microcontroller sleep so the alert path can start between reports.
Technical boundaries. The temperature curves are sketches, and the crossing-to-delivery bracket is unscaled. Sample timing for the routine batch is unspecified. The scheduled starts can be counted in the chart, while total radio starts including alerts, energy use and delivery latency are listed as measurements to collect.