Can a sleeping sensor meet the command deadline?
Can a sleeping sensor meet the command deadline?
Try Advance with Step to reveal the receiver’s Off interval and locate the next receive opportunity on the shared timeline.
An earlier report arrives
The application had received a report while the sensor was awake.
Application
Gateway
Battery sensor
Prior report received
Command at application
What should you test before approval?
Shorter sleep schedule
Suitable receiver path
Measure submission to command execution
Check energy impact
Which event must the test record to show the command worked?
- Command submitted
- Receiver awake
- Command executed · Correct
Record command execution to verify the outcome and compare the elapsed time since submission with the deadline.
Observe The 30-second deadline bracket appears inside the 10-minute Off interval. Its square changes to Deadline missed while the wake diamond is relabelled Earliest possible reception.
Explain The 30-second deadline starts at submission and expires while the receiver is off. The sensor can listen only once it wakes, and command execution still needs evidence.
Technical boundaries. The timeline uses one maintenance command submitted during a 10-minute sleep and a 30-second deadline for that command. Waking marks the earliest chance to listen. Buffering, delivery and execution still need evidence, and the review calls for measuring elapsed time from submission to execution and checking energy impact.