Separate Axis Mapping Readout and Host Decision Errors
Separate Axis Mapping Readout and Host Decision Errors
Where does the evidence first disagree?
Accelerometer benchPredict the static sign
Fixture and mounting
Upward package +Z → product +Z
Raw samples and bus
DATA_FORMAT · full resolution, right justified, signed two’s complement, ±2 g for this static pose.
Host and release
Predict the signed product direction before stepping.
Decode the package reading
Fixture and mounting
Upward package +Z → product +Z
Raw samples and bus
DATA_FORMAT · full resolution, right justified, signed two’s complement, ±2 g for this static pose.
Combine the matching low and high bytes in register order. Decode as signed using the recorded DATA_FORMAT.
Decoded package Z · positiveHost and release
Product result covered.
Locate the first divergence
Fixture and mounting
Upward package +Z → product +Z
Raw samples and bus
[Xlo, Xhi][Ylo, Yhi][Zlo, Zhi]Combine the matching low and high bytes in register order. Decode as signed using the recorded DATA_FORMAT.
Decoded package Z · positiveUse a bus trace to confirm the bytes belong to the same sample.
Host and release
Expected product +ZReported product −ZFirst divergence · package-to-product mapping.
Replay a false alert
Fixture and mounting
Final case and mount. Keep the dynamic trial range and timing schematic.
Raw samples and bus
Capture raw samples, pin and source observations alongside the applied motion.
Host and release
Ignore normal shakeFalse alert| Track | Quiet baseline | Normal shake |
|---|---|---|
| Applied motion | Quiet | Normal shake |
| Raw samples | Record baseline | Compare with trial input and settings |
| Interrupt and wake | Record baseline | Compare pin, source and wake |
| Application alert | Waiting | False alert |
Replay a missed drop
Fixture and mounting
Final case and mount. Keep the dynamic trial range and timing schematic.
Raw samples and bus
Raw sample reaches the configured range limit.
Possible saturationHost and release
Missed dropCompare against the planned event and the recorded pass limits.
| Track | Before drop | Planned drop |
|---|---|---|
| Applied motion | Quiet | Drop under recorded conditions |
| Raw samples | Baseline | Reading reaches the configured limit |
| Interrupt and wake | Capture the baseline | Review mapping, latch, clear, and host latency |
| Application alert | Waiting | Missed drop |
Assemble the release record
Known-pose record
Fixture, mapping, sign and scale, register readback, and raw bytes.
Dynamic-trial record
Final mount, shake and drop input, sampled response, clipping checks, false alerts, and missed events.
Compare timing and current with the recorded criteria. Carry unresolved transport conditions into field follow-up.
In this face-up fixture, package +Z points up and maps to product +Z. Predict the sign.
Technical boundaries. The pictured static check uses a face-up pose with a ±2 g setting, while the bench check calls for six orientations. The shake and drop tables contain illustrative evidence. The drop example flags possible saturation, and the release record still awaits measured evidence.