Sensor and gateway restart order
Sensor and gateway restart order
Sensor and gateway restart order
Step-throughSensor restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Baseline gateway read · Baseline raw matches the known register sample. Probe B map → baseline moisture matches the trusted baseline reading.
Target observations
Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance
Gateway restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Baseline gateway read · Baseline raw matches the known register sample. Probe B map → baseline moisture matches the trusted baseline reading.
Target observations
Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance
Sensor restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B power-cycles
Gateway
Gateway running
Restart begins.
Target observations
Last good (historical) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Gateway restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway power-cycles
Restart begins.
Target observations
Last good (historical) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Sensor restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B power-cycles
Gateway
Gateway running
Observed I²C no-ack at register read → Bus communication fault. Freshness limit exceeded · The historical record is marked stale when its age exceeds the map’s freshness limit.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Gateway restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway power-cycles
Gateway evidence unavailable during downtime. Freshness limit exceeded · The historical record is marked stale when its age exceeds the map’s freshness limit.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Sensor restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Gateway read after communications return.
Validation · stale-cache candidate
Baseline raw, original map reference and original acquisition provenance. Later gateway read recorded separately.
Keep this candidate outside the accepted target row.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Gateway restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Gateway read after communications return.
Validation · stale-cache candidate
Baseline raw, original map reference and original acquisition provenance. Later gateway read recorded separately.
Keep this candidate outside the accepted target row.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Sensor restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Gateway read after communications return.
Validation · stale-cache candidate
Baseline raw, original map reference and original acquisition provenance. Later gateway read recorded separately.
Keep this candidate outside the accepted target row.
Validation · new register sample
Observed post-restart acquisition A-new tied to captured sample R-new; Probe B map produces M-new.
Captured raw: R-new · Known expected register sample: R-ref.
Mapped moisture: M-new (fixture unit) · Trusted source moisture: M-ref (fixture unit).
Compare the two references before accepting.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Gateway restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Gateway read after communications return.
Validation · stale-cache candidate
Baseline raw, original map reference and original acquisition provenance. Later gateway read recorded separately.
Keep this candidate outside the accepted target row.
Validation · new register sample
Observed post-restart acquisition A-new tied to captured sample R-new; Probe B map produces M-new.
Captured raw: R-new · Known expected register sample: R-ref.
Mapped moisture: M-new (fixture unit) · Trusted source moisture: M-ref (fixture unit).
Compare the two references before accepting.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
Sensor restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Gateway read · new acquisition A-new, captured sample R-new.
Validation · stale-cache candidate
Baseline raw, original map reference and original acquisition provenance. Later gateway read recorded separately.
Keep this candidate outside the accepted target row.
Validation · new register sample
Observed post-restart acquisition A-new tied to captured sample R-new; Probe B map produces M-new.
Captured raw: R-new · Known expected register sample: R-ref.
Mapped moisture: M-new (fixture unit) · Trusted source moisture: M-ref (fixture unit).
R-new matches R-ref. M-new matches M-ref.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
First post-gap record · Good · Greenhouse Probe B, moisture point · Acquisition A-new · Raw sample R-new · Mapped moisture M-new (fixture unit) · Applied map: Probe B map.
Quality evidence · Post-restart acquisition verified; R-new matches R-ref and M-new matches M-ref.
Gateway read event · Read of R-new tied to acquisition A-new.
Gateway restarts
Greenhouse I²C Probe B · same symbolic fixture
Sensor
Probe B running
Gateway
Gateway running
Gateway read · new acquisition A-new, captured sample R-new.
Validation · stale-cache candidate
Baseline raw, original map reference and original acquisition provenance. Later gateway read recorded separately.
Keep this candidate outside the accepted target row.
Validation · new register sample
Observed post-restart acquisition A-new tied to captured sample R-new; Probe B map produces M-new.
Captured raw: R-new · Known expected register sample: R-ref.
Mapped moisture: M-new (fixture unit) · Trusted source moisture: M-ref (fixture unit).
R-new matches R-ref. M-new matches M-ref.
Target observations
Last good (historical, stale) · Baseline event · Greenhouse Probe B, moisture point · Baseline moisture (fixture unit) · Good: raw and trusted reference checked · Baseline raw · Probe B map · baseline acquisition provenance.
Observation gap · No newly accepted record.
First post-gap record · Good · Greenhouse Probe B, moisture point · Acquisition A-new · Raw sample R-new · Mapped moisture M-new (fixture unit) · Applied map: Probe B map.
Quality evidence · Post-restart acquisition verified; R-new matches R-ref and M-new matches M-ref.
Gateway read event · Read of R-new tied to acquisition A-new.
Other source types
Wireless recovery may require session counter or key checks. Analogue inputs may need time to settle.
Seed the same verified fixture
Both drills start with the same verified Probe B record stored at the target.
Technical boundaries. Both drills use the same symbolic Probe B fixture and fixture units. The acceptance check compares the new register sample and mapped moisture with their references. Wireless session counter or key checks and analogue settling appear only as examples of considerations for other sources.