Recover a Motor Alert After Restart
Recover a Motor Alert After Restart
Trace A9 from the saved input to the work-order receiver. Watch where processing resumes and where an alert becomes a work order.
Checkpoint recovery · Sink deduplicationSaved input
Same motor · within the reviewed event-time window
- V17 Vibration event
- T22 Temperature event
Processor
Work-order receiver
Checks the alert key
Creates a work order only if the key is absent. Saves the key with the order.
Acts on every alert
Creates a work order on each delivery.
Where must A9 be remembered to prevent another work order?
Reveal answer
At the work-order receiver, across deliveries.
Separate test · Late T22
For T22 beyond the allowed cutoff, choose Reject with reason or Issue a correction. Show the outcome on the dashboard and retain the alert identity. The hourly total still needs its own lateness and correction rule.
Technical boundaries. The saved events are for the same motor inside the reviewed event-time window. The duplicate delivery goes straight to the receivers, and both replays reuse the original inputs and rule. Late T22 is a separate test prompt, and the hourly total needs its own correction rule.