When the Room Reading Expires

When the Room Reading Expires

Try Press Step to move to 125 s and predict what the Room display will show when the freshness window closes.

Read the display as freshness expires

Observe

Room display

Last accepted temperature · Symbolic reading

Status · Fresh

Receipt and deadline

/sensors/temp accepted at 100 s · Max-Age 30 s

Receipt · 100 sDeadline · 130 s

Time marker · 100 s

The notification received at 100 s grants 30 s of freshness, ending at 130 s.

Observe At 125 s the Room display still says Fresh. At 130 s it keeps the symbolic reading under Last known, marks it stale, and labels the current temperature unknown.
Explain The accepted notification at 100 s grants 30 s of freshness through its Max-Age. An accepted refresh response would supply its own receipt time and Max-Age for a new deadline.

Technical boundaries. The temperature is represented by a symbolic reading. The timeline marks local receipt, and establishing when the sensor physically sampled the room requires payload evidence. The trace ends with a refresh request and no accepted reply, so it shows no renewed freshness window.