How Sampling Folds a Frequency
How Sampling Folds a Frequency
Compare the waveforms at the sample guides
SamplingAnalog inputs sampled at 80 Hz
Normalized amplitude
50 Hz (solid)
Analog inputs sampled at 80 Hz
Normalized amplitude
50 Hz (solid)
Analog inputs sampled at 80 Hz
Normalized amplitude
50 Hz (solid) · 30 Hz (dashed)
Analog inputs sampled at 80 Hz
Normalized amplitude
50 Hz (solid) · 30 Hz (dashed)
Fold the frequency
|50 Hz − 80 Hz| = 30 Hz
Filled dots and hollow rings occupy the same sample positions.
Analog input → Analog anti-alias low-pass filter → ADC
Analog input
Analog anti-alias low-pass filter
Before conversion
ADC
80 samples/s
Schematic filter response
Relative response
Wanted passband40 Hz (80/2)
Nyquist frequency50 Hz
Unwanted energy
Sufficient attenuation above Nyquist, including at 50 Hz.
The converter observes the input only at the marked instants. What might it miss between them?
Technical boundaries. The waveform comparison uses normalized cosines that start together at a positive peak and shows one shared repeat interval. The filter panel gives a schematic response with relative levels and leaves the actual attenuation and filter design unspecified.