Separate DAC Quantization from Update Timing
Separate DAC Quantization from Update Timing
Try Press Step once to compare the first-update voltage error for the 8-bit and 12-bit grids at the same update rate.
Compare levels, timing and images
DAC tracesAll traces share a 5 V reference and a 1 kHz target. Rust is the target and teal is held output. Ties choose the lower code on the endpoint-scaled voltage grid.
Sample and hold on the 8-bit grid
The voltage grid sets the possible heights. The update clock sets when the output can change.
8-bit · 44.1 kHz updates
First update · voltage error
12-bit · 44.1 kHz updates
Same midpoint scale · compare brackets
Dashed trace · 8-bit output. Rust curve · 1 kHz target. Teal steps · selected held output.
8-bit · 44.1 kHz updates
8-bit · 88.2 kHz updates
8-bit · 44.1 kHz updates
8-bit · 88.2 kHz updates
Baseline update clock
Faster update clock
8-bit · 88.2 kHz updates
Faster clock · attenuated images
- Held DAC outputRaw staircase
- Low-pass reconstruction filterBandwidth, delay and settling matter
- Intended loadMeasure what reaches it
Observe The voltage error bracket shrinks from 9.8039 mV at 8 bits to 0.6105 mV at 12 bits. In the timing comparison, the tick interval shrinks from 22.68 to 11.34 microseconds as the update clock speeds up.
Explain The 12-bit grid has closer voltage levels, so its nearest code is closer to the target at the first update. Raising the clock to 88.2 kHz shortens the hold interval while keeping the 8-bit levels available.
Technical boundaries. The plots use an endpoint-scaled voltage grid, a 5 V reference and a 1 kHz target, with ties assigned to the lower code. The spectrum draws image heights schematically. The filter view illustrates attenuation and leaves the waveform at the intended load to be measured.