Compare Impact Sampling Phases
Compare Impact Sampling Phases
Try Press Step to place the first sample grid on the 20 ms impact and locate the ring marking the highest recorded sample.
Move the sample grid across a fixed pulse
Sampling phaseSchematic impact
Shifted grid · 50 Hz
Acceleration is vertical and time is horizontal. The dashed horizontal line marks 3 g. The upper bracket spans the 20 ms impact.
Schematic pulse. A recorded sample must be above 3 g to pass the acceleration check.
Dots show recorded samples. The ring marks the highest recorded sample.
The lower bracket spans the 20 ms between samples.
Start with the impact
The impact lasts 20 ms. The acceleration rule triggers only when a recorded sample exceeds 3 g.
Observe The ring first sits at the crest above the 3 g line, then moves below that line on the shifted grid. The outcome label changes from Passes acceleration threshold to Misses acceleration threshold.
Explain Both grids use 20 ms spacing, but the shift changes which points on the same pulse are recorded. Only the crest-aligned grid records a sample above 3 g, so only that grid passes the acceleration check.
Technical boundaries. The pulse is schematic and stays fixed as the sample grid moves. The replay compares two phases at 50 Hz and uses a single acceleration rule requiring a recorded sample above 3 g. The outcome labels refer to that check alone.